RAM Connection CONNECT Edition version 11.01.00.227

Posted By: scutter
RAM Connection CONNECT Edition version 11.01.00.227

RAM Connection CONNECT Edition version 11.01.00.227 | 238.2 mb

Bentley Systems Incorporated, the leading company dedicated to providing comprehensive software solutions for sustaining infrastructure, has released the 11.01.00.227 version of RAM Connection CONNECT Edition. This software offers the best flexibility for the design of different shear, moment, braces, splices and base plates connection types.

Perform analysis and design of virtually any connection type and verify your connections in seconds, all with comprehensive calculations, including seismic compliance. Increase your productivity with optimized workflows and full integration of 3D design models, including the ability to customize the application with your preferences. Efficiently design and optimize a myriad of connections included in the AISC (ASD and LRFD), EC3, GB, and BS specifications. Quickly complete all your connections, such as shear and moment connections, braced frame connections, column/beam splices, and base plates.

RAM Connection CONNECT Edition Update 1 (11.1.0.227) Release Notes:

RAM Connection CONNECT Edition 11.1.0 Release Notes – Updated May 2017

Enhancements:

- IS 800:2007 Indian steel design standard for connection design.
- RAM Connection now includes Bentley CONNECT Advisor v10.0.2 which is a CONNECT service enabling Bentley users to have real time access to LEARN content, recommendations for more productive workflows and the ability to embed an Expert Engineer to their CONNECTED project.
- Small improvements to the design reports for better reading.
- Update to Structural Synchronizer (ISM) 6.0.

Resolved Issues:

- A miscalculation of the gusset buckling Whitmore capacity when the brace formed a small angle with the beam has been corrected.
- The effective length factor “K” was being calculated incorrectly for the Whitmore buckling code check in gusset connections.
- The length used to calculate web crippling in Gusset connections used a unitary equivalent length when Design Guide 29 states the actual lengths have to be used. This has now been updated to comply with the aforementioned guide.
- The prying effects calculation for Cap Plates, erroneously used the beam flange thickness instead of the cap plate thickness. This has been corrected.
- For the calculation of normal stresses in a beam-to-gusset interface, an equation from a different reference was being used. The application has now been updated to use the equation in Design Guide 29.
- The beam web thickness check for Single Plate connections with a skew angle, has been eliminated by recommendation of the AISC Solution Center.
- For EN 1993 connection design, the software followed a criterion only applicable for tension/compression members for the bolt pitch (or gage). Now it follows BCSA recommendations the same.
- The Cap Plate web crippling check followed the same procedure for AISC 360-05 and AISC 360-10. This has now been corrected to follow the correspondent method, since it has changed from the 2005 to the 2010 edition.
- A new warning was added for Stiffened Seated connections with HSS columns, in which the length of seat plate exceeds the flat width of the section.
- Other several minor fixes.

RAM Connection CONNECT Edition version 11.01.00.227

About Bentley Systems, Incorporated

Bentley is the global leader dedicated to providing architects, engineers, constructors, and owner-operators with comprehensive architecture and engineering software solutions for sustaining infrastructure. Founded in 1984, Bentley has nearly 3,000 colleagues in more than 45 countries, $500 million in annual revenues, and, since 2001, has invested more than $1 billion in research, development, and acquisitions.

Product: RAM Connection
Version: CONNECT Edition 11.01.00.227
Supported Architectures: 32bit / 64bit
Website Home Page : www.bentley.com
Language: english
System Requirements: PC
Supported Operating Systems: Windows 7even / 8.x / 10
Size: 238.2 mb
Please visit my blog

Added by 3% of the overall size of the archive of information for the restoration

No mirrors please

RAM Connection CONNECT Edition version 11.01.00.227