Tags
Language
Tags
May 2024
Su Mo Tu We Th Fr Sa
28 29 30 1 2 3 4
5 6 7 8 9 10 11
12 13 14 15 16 17 18
19 20 21 22 23 24 25
26 27 28 29 30 31 1

Promis.e CONNECT Edition Update 11

Posted By: scutter
Promis.e CONNECT Edition Update 11

Promis.e CONNECT Edition Update 11 | 8.7 Gb
Languages Supported: english or 中文

The Bentley Electrical and Control System Design Software development team is pleased to announce the availability of Promis.e CONNECT Edition Update 11 is an intelligent 2D/3D electrical system design application that delivers projects faster and with fewer errors than traditional CAD.

New and Changed in Promis.e CONNECT Edition Update 11
The following items summarize the new features and enhancements in the Promis.e CONNECT Edition Update 11 release:

Add a new Copy Balloon Callouts option to allow users to maintain Balloon Callout drawing annotations.
Users are able to enable the toggle “Copy Balloon Callouts” when user has enabled “Maintain Device ID – Complete” and Source and Target projects are different.
- Copy Balloon Callouts is enabled, if no conflict, the software will copy Balloon Callouts from source project to target project. If target project contains one or more some complete device IDs, then the software will display Engineering Design Consideration dialog.
- Copy Balloon Callouts is disabled, Balloon callouts will be removed from copied pages.

Promis.e CONNECT Edition Update 11

Add checking of Microsoft Access Database Engine version.
The software will check if Microsoft Access Database Engine is with a bad version. If yes, the software prompts the warning dialog. User is ability to check the problem in the file “Registry_File_Check.txt” under installation folder “\ProgramData\Bentley\OpenUtilities Substation CONNECT Edition\Configuration\Datasets\Substation\Config\”.

Promis.e CONNECT Edition Update 11

Add the warning message when SQL server is down or not available.
If user executes some commands such as Copy, Move, Scale, Rotate, Mirror, Delete and Stretch, and SQL server is suddenly down or not available, then the software will pop up the warning message.

Promis.e CONNECT Edition Update 11

In ProjectWise integration, support Read-only permission for ProjectsOptions.xml.
User is able to create new page in Substation Project with Read-Only access to the ProjectOptions.xml.

Promis.e CONNECT Edition Update 11

Shared cell symbol is placed on active level.
A symbol is saved with “Use Shared Cell” option in Symbol Create Wizard. When the symbol is placed, it will be placed on active level.

432004 [Delete Project]Creating a project with a page having reference, and backup the project, then delete the project, it popups unexpected dialog.
432594 [Project Manager] Pages cannot fresh after switch from Favorite tab to Local Folder or ProjectWise in Project Manager
537866 [Update Wiring Diagram]Updating wiring diagram pages, It popups error dialog in some special condition.
553076 [PW Integration][Update/Refresh Page] When update or refresh one closed page and keep another page opened, it prompts check in twice
601382 [Dialog Configuration] Select Part Number dialog configuration not saved in Registry like Parts Database Manager
613415 [Re-Sequence Wire Link][Performance] It takes about 2 min 50 sec to open the Re-Sequence Wire Link dialog in users Substation project
716988 [Project Manager]Description is not getting update in Project directory (name include &)
727238 [WireManager] Unhandled exception occurs when close the Wire Label Preferences dialog in Wiring Manager dialog
728021 [Modify Page][Multi Project Database] Modify page reports error on two different database projects
728030 [Symbol Text] After modify I/O text, many hidden symbol texts will show on the drawing
729523 [PLC Attributes]PLC attributes value are visible while inserting but not visible while editing the symbol
730275 [Symbol Attribute] The user is facing the issue that the position of the Part Number Attribute in a symbol is not maintained when the symbol is placed / updated
738089 [PW Integration] Ecad.dgn file should be removed from PW project
740640 [PW ][Catalog]The initial catalogs loaded in the Catalog Manager don’t same with that in Modify Catalog Path after switch launching software from local to with PW.
744085 [Auto Backup]It should give a detailed information in AutoBackup.log file for a project missing required file or database connection.
745709 [PLC Text] Internal Error message when adding apostrophe to PLC I/O text which has family assigned
745900 [New Page][Title Block Sheet Model]Create a page with toggle of Place title block in Sheet Model turned on, modify the page description, the modified info cannot display in the sheet model in time.
747700 [PW Integration] Project Path is not updated in database when a folder is renamed in PW Explorer that contains Substation Projects
748268 [PW Integration] Custom Page Attributes value updated via PWExplorer cannot be seen in Substation page properties
749184 [CreateCatalog_PW] DeviceDB Error Message: Could not find file 'xxx\Catalog.mdb' appears after create a catalog and create a page by default
754430 [AutoBackup]The AutoBackup.log file logs the details of folders that are not project folders as Invalid project path
763967 [SQL Server] When SQL Server is down or not available Promis.e should give correct error message indicating the issue
763967 [SQL Server] When SQL Server is down or not available Promis.e should give correct error message indicating the issue
764454 [Multi-Language MDB] Multi_language MDB is not changed When active workspace is changed if switching between projects with different workspace
764454 [Multi-Language MDB] Multi_language MDB is not changed When active workspace is changed if switching between projects with different workspace
774409 [Rebuild Project Database] Multiple users can Rebuild Project Database for a Project at the same time
775523 [Title Block] When Title Block is placed in Sheet the page descriptions are not updated in title block after they are saved
775581 [Modify Page] For page with Title Block placed sheet the modify page dialog cannot be accessed by right click on the title block
781211 [Cable Manager] An error occurs when opening Cable Manager in user project
792099 [Options]Validation Prompts ->Prompt for saving page when switching pages doesn't work well and an error appears
792718 [Create Symbol] Symbol DGN not created when new symbol created using Import Symbol Graphics method
800409 [Rebuild Project database] Cross reference is shifted to spare after rebuilding project database
800623 [Balloon Number] Balloon Number cannot be seen in construction drawing when the balloon number is located in Parts Database
800969 [Configuration Variables] ELEC_CATALOG_PATH Level is automatically changed from WorkSpace to WorkSet after copy a catalog and click OK in Catalog Manager -> Modify Catalog Paths
806331 [Modify Page]Page descriptions details are not updated in title block if title block is placed in sheet model when page is open
815307 [Multi DB][Insert Symbol] Insert symbol reports error after switch project with different DB
847749 It reports error to select some page(s) of users Project
848735 [Copy Page]The part number is incorrect after copying panel layout page and wiring diagram page.
855017 [Catalog Manager] When switching to a project associated with different workspace then current the catalogs list in Catalog Manager are not updated accordingly
861517 [Sub ID]It cannot popup the expected EDC dialog when inserting a symbol with more than two sub ids in panel layout/wiring diagram page.
862139 [Display Part Numbers]The part number cannot display in the drawing.
862255 All Cross Reference goes to the left down corner of the drawing.
863609 [Balloons] balloon callouts display incorrect Balloon Number values after user edits balloon number
863646 [Balloons] balloon callout graphics change position after user makes edits to Balloon Numbers
865676 [Replace Symbol] connection point order not always maintained when user executes Replace Symbol or Update Symbol
868408 [Page Copy][Wire Link]Cross Reference / ID text position on copied page does not match source page
871021 [Catalog Manager] After rebuild catalog, the categories in the catalog are missing.
871043 [Catalog Manager][Create Family]Create a new family, it cannot be saved in the catalog.
872781 [Create Symbol]Modify a symbol, add cp, and place the added cp, it popups error dialog.
872786 [Catalog Manager] Copy a catalog to the catalog path, it cannot list in the catalog manager.
874064 [Symbol Create Wizard][Place Connection Points]Clicking Place button reports error.
874067 [Create Macro]Manage->create macro->It cannot call out the create macro dialog using the attached project.
876097 [Symbol Create Wizard] Insert Symbol in ‘Specify Device ID’ step reports error.
876498 [ PW Integration][Project Manager] Click Thumbnails in Project Manager reports error with PW project
880979 [Delete Page] After a page is deleted the details associated with Balloon Callout that were present on the page are not deleted from the dbo.SymbolBalloonGroup table in Database
885059 [Wire Sizing] It occurs error to use wire sizing feature.
885153 [Project Manager] Project icon cannot be updated with open page and close page
885799 [Copy Page][Wire Link] Wire link ID in copied page cannot match source page
885815 [Project Manager][New Page] Create new Wiring diagram page occurs crash in the attached project
889656 [New Project] It reports error during creating project after launch Promise at the first time.
889750 [Copy Balloon]Sometiems the copied balloon callout inserted by Device is not correcet.
889778 [Orphaned Balloon][Move] Move Orphaned Balloon will crash
890303 [Copy Balloon]There is a unexpected Orphan balloon record after copy pages with reference files.
890396 [Copy Balloon]The details info are not correct if the device has more than two part numbers. And it lost the revision number info.
893910 [Balloon by Device] Modify/Move/Delete balloon placed by device two times report error
897082 [Wire Link] wire link cross-referencing not working properly when user is using ProjectWise Managed workspace
897252 [Re-sequence Wire Link]There are duplicate records in the Re-sequence Wire Link dialog.
897963 [Autobackup] autobackup stops and waits for user input with Alert Message "The project will be updated to new version"
897968 [ProjectWise Integration] rename one or more folder in project path causes Alert Message "The project will be updated to new version" to appear
898681 [Insert Symbol by Device ID]The software will crash if insert all child symbols groups by insert symbol by Device ID.
910002 [Ribbon][PLC Generator] It reports error to click PLC Generator ribbon.
915902 [Insert Macro]Create a macro and then insert it in the same page with all options not maintain, the device tags are not correct in the drawing.
923444 [Sub ID] It cannot popup the expected EDC dialog when inserting a symbol with more than two sub ids in schematic page.
923661 The General_Cables type of wire drawn by Draw Wire command can’t be seen by default on Single Line Mode page after paste a circuit.
930920 [PW][AutoBackup] AutoBackup failed for valid PW Project
930939 [Parts Database] The default displayed parts database is not refreshed according to the selected one in Configuration Variables
933459 [Project Manager][Delete Project] a different project having same project_id in another Project Database is deleted
933879 [Options] Components Center is disappeared in Options in Promis.e U11
934580 [PW] Fail to launch software with PW with the warning of ‘Common data folder does not exist’.
935447 [Device Properties] A strange EDC appears when click OK in Device Properties after modify Device Tag and select a child for a symbol
935481 [I/O Text] Fail to update I/O Function Text in Parent chart symbol for the selected Child
937692 [Publish Project To Server] Publish Project To Server is disappeared from the right click menu on a project in Promis.e
937883 [Balloon]Activate the reference file the second time, the balloon callout inserted by activate the reference file is not correct.
938965 [Project Publisher] It has problem to publish some Promise sample projects and PGE project.
939151 [PW integration][Project Selection] It cannot list pages in Project Manager after restart Substation with pw
940012 [Create Symbol]Place two created new symbols in the wire, and the wire between the two symbols does not has the from and to information.
945683 [MicroStation Mode] The WorkSpace and WorkSet are not loaded automatically after launch Substation/Promise MicroStation Mode.
945683 [MicroStation Mode] The WorkSpace and WorkSet are not loaded automatically after launch Substation/Promise MicroStation Mode.
946469 [PW integration][project Manager] It cannot list demo projects' drawings in Project Manager thumbnails
947123 [Office update][ Access Database Engine] Start and close software will crash after office update
948300 [Copy Page]Copy page with terminals to other project, there are some duplicate records in the insert symbol by device id dialog.
957969 [Rebuild Project] Cannot rebuild project database when the software is closed during the rebuild project

Promis.e CONNECT Edition Update 11

Promis.e CONNECT Edition Update 11

Promis.e is an intelligent 2D/3D electrical system design application that delivers projects faster and with fewer errors than traditional CAD. Promis.e automates tedious drafting and employs an intelligent model that cross-references schematics, 2D layouts, 3D equipment models, and reports.

The primary focus of Promis.e is as a tool for drawing electrical schematics. This includes schematics for control, power, single lines, wire diagrams, terminal plans and even pneumatic and hydraulic control. It also has functionality for layout and physical design of the control enclosures. BUT It is not a simple drafting tool. Every wire, every connection, every component, and every piece of information about those items, and the different ways you may need to combine that information is maintained in a database. Connection information, cross referencing, technical specifications, ordering and pricing information, mounting layouts, and component labels and nameplates – all of this is encompassed by the software and provided in the form of drawings, lists, reports and databases. And all of this output, because it is computer-based, can be provided with greater speed, efficiency, and accuracy than was possible previously.

With Promis.e, the software is intelligent enough to take over some of these formerly-manual tasks. For example, when creating a schematic, the software can prompt a unique ID tag for each symbol so that user doesn't have to keep track of these assignments. The software also automatically cross references the location of related symbols in real time so that the user instantly knows where each ID is used. Wire numbers can be assigned automatically, again freeing the user from having to remember which numbers have been used. Should the user attempt to re-use an existing ID or wire number, error-checking functions immediately flag the situation.
The Promis.e software is able to provide this intelligence by grouping work into projects.

The application is used around the world to design industrial machine controls as well as electrical systems for process plants, mines, and rail signaling.

Rail Signaling Design with Bentley's Promis.e


Learn how to perform rail signaling design with Bentley's Promis.e.
Bentley Systems, Incorporated. is the global leader dedicated to providing architects, engineers, constructors, and owner-operators with comprehensive architecture and engineering software solutions for sustaining infrastructure. Founded in 1984, Bentley has nearly 3,000 colleagues in more than 45 countries, $500 million in annual revenues, and, since 2001, has invested more than $1 billion in research, development, and acquisitions.

Product: Promis.e
Version: CONNECT Edition Update 11 (10.11.00.058)
Supported Architectures: x64
Website Home Page : www.bentley.com
Languages Supported: english or 中文
System Requirements: Windows *
Size: 8.7 Gb

Promis.e CONNECT Edition Update 11

Please visit my blog

Added by 3% of the overall size of the archive of information for the restoration

No mirrors please


Promis.e CONNECT Edition Update 11