Raceway and Cable Management CONNECT Edition V10

Posted By: scutter
Raceway and Cable Management CONNECT Edition V10

Raceway and Cable Management CONNECT Edition V10 | 7.0 Gb

The Bentley development team is pleased to announce the availability of Raceway and Cable Management CONNECT Edition V10 (10.00.00.127). This integrated software system provides complete layout, routing, and material estimating functions in a single, integrated system and creates the framework for an effective workfl ow spanning all phases of the design, from initial concept to detailed layout and construction.

What's New in Bentley Raceway and Cable Management CONNECT Edition V10 (10.00.00.127)

New Workflow-Focused User Interface
- BRCM tools are now organized into eight tabs; each one focused on different workflow steps. Each section contains only tools required to complete the workflow. The goal of this enhancement was to increase user’s productivity by focusing only on tools relevant to a specific workflow
New Configuration System
- In line with the MicroStation CONNECT configuration system, BRCM is now taking advantage of the workspace> workset configuration system.
3D Cables Visualization
- After cables are routed through raceways, Create 3D Cable option can be used to visualize cables inside a raceway system. Visualized cables cannot be edited.
- Cable bend radius is the same as cable tray bend radius, and the default option cannot be changed at this time. Additional enhancements (making sure that cable maximum bend radius is smaller than cable tray bend radius) are work in progress.
Converting Arch and Circle into a Raceway
- Users can now convert aches, circles and other complex shapes into a raceway system. In previous versions, BRCM could only convert straight lines into a raceway. Standard Raceway generator function is used to convert any shape into a raceway.
Clash Detection Module in BRCM
- Users can now take advantage of Clash Detection module at no additional charge. Clash detection tools are available from Modeling>Analyze or Drawing>Analyze menus.
Support for Citrix Environment
- BRCM can now be configured to work in a Citrix environment.

911638 The software crashes when double clicking a routing line to navigate to a raceway dng file when integrated with ProjectWise.
911640 The software crashed when using the navigate tool to navigate to a raceway/equipment dng file when integrated with ProjectWise.
921419 In a particular project, selecting any routed cable would result in an unhandled exception error.
909146 An unhandled exception error would occur if you tried to delete a voltage level item in the Options>Raceway Specifications>Raceway Categories dialog.
151961 Corrected a message box displayed when previewing or exporting a report that stated, "Cable Manager Loading data…" The message now properly refers to the "Output Manager" instead of the "Cable Manager."
759383 When placing a manhole using the Equipment Manager, the measured inside height should match the specified Inside Height and the measured outside height should equal Inside Height + 2 x Wall Depth.
741451 When inserting a raceway bend and connecting it to a straight the raceway guid value of the bend would become duplicated with that of the straight piece rather than being assigned an unique value.
889496 The Detail_Cable_Route_List report when run on a particular project reported all lengths as 2.0 and did not include the raceway IDs in the RW Segment ID column.
910158 Fixed the incorrect Reducer Lengths for the Cooper Cable Ladder Series 2,3,4 & 5 Steel catalog
633478 The performance of various operations in the Cable Manager have been improved which include, loading data, Auto Connect, loading Routing Manager, closing Routing Manager, Save to Project Model, Refresh Routing Model, and reopening the Cable Manager after routing is performed.
361450 Repeated raceway part creation would continually increase the memory usage until the software would crash.
652968 Publish_i-model could not create relationships between cables and other elements in the demo project BRCM_PLANT_US_COMP.
709750 The BRCM Tools > Display Manager dialog had labels that could not be localized in other languages.
614827 iModel publishing failed for a particular project.
492213 Executing 'Reroute Cables with lower Priority’ in the Routing Manager multiple times will produce an error or crash BRCM when you attempt to exit the Routing Manager.
902505 The Conceptual Design BOQ report is empty and the Length in the Conceptual_Cable_Schedules is zero when using the Conceptual Design Sample project.
637262 Updates to raceway IDs were not reflected in the Cable Manager and outputs unless you performed a new automatic routing which is not always desirable.
867859 Raceway that does not match the Context ID in the LIB_Raceway.xml was appearing by default in the Raceway Router or Duct Bank Router dialogs by mistake.
374441 The Tee fitting for the Generic Cable Tray Square raceway should not have a radius.
289520 When selecting Refresh Routing Model a status box was displayed which remained on the top of all other application windows. The status box should not be displayed on top of other unrelated applications so that it doesn't impede users from working in other applications while they wait for the command to finish.
656736 After Duct bank is copied, the ID cannot be modified and the duct bank cannot be stretched.
374242 In certain scenarios the Duct Bank Router > Connect command when using the branch option is unable to insert parts such as elbows on the selected conduits.
626673 Unable to add new raceway specs in Conceptual design.
947068 In the Raceway Catalog Creation dialog, an error appeared when adding a raceway size and pressing Enter.
947520 The Raceway Offset tool could crash the software when selecting a MV voltage level in the Raceway Properties grid.
947577 In the Raceway Router dialog, double clicking on Dividers and then setting focus to the Voltage Level cell could cause the software to crash.
816269 In the Chinese build, the software cannot generate 3D Cable visualization after importing the database xml files.
378258 Using the Raceway Catalog Creation tool to define fittings could result in incorrect chamfer and end straight lengths on vertical bend fittings.
903656 The 2D Extraction raceway labels were displaying the wrong weight and height values such as 3 instead of 300mm.
709747 Some labels in the Create New Raceway Catalog were not localizable in other languages.
867855 The Add, Copy, Paste & Delete buttons in the Equipment Manager were disabled in the Chinese localized build.
867901 If you attempted to create new equipment using a template and then tried to edit Equipment Properties an error occurred and the equipment was not created.
390666 When routing raceway and inserting a cross over fitting the variants list ends up with duplicate entries in it.
722422 The Excel import and i-model import for cable lists result in an exception error regarding missed resources.
665853 When using the Validate Active Dataset command and no error was found an awkwardly worded message was displayed.
344768 An "Incompatible item type libraries" message was displayed when publishing an i-model.
874904 Selecting multiple objects and right clicking DisplaySet clears the selection set rather than executing the command.
921096 The software crashed when updating the existing 2D section 3 in the example project BRCM_PLANT_US_Comp.
639120 The path to the EC schema files such as ECClasses.xml was hard coded, but should be configurable.
569741 The Trade width for raceway tees ($TT) does not work correctly in descriptions on reports.
562104 There are the wrong fittings defined in catalog 'Rico Wide Span Cable Ladder System 150'. All bends, tees, crossovers have to be round and not square, as well as defined in 'Rico Wide Span Cable Ladder System 200' for example.
423891 When integrated with ProjectWise and you attempted to use the Output Manager to export a report you were prompted two times to specify the ProjectWise Path for the report and it did not default to the correct path. The software should now present a dialog to save the file in the folder specified by the BRCM_PW_SUBFOLDER_REPORTS variable first. If the user selects Cancel, then a dialog to save in the local file system is presented.
179736 Schedule 80 conduits don't have correct body style Tee fitting.

Raceway and Cable Management CONNECT Edition V10

Raceway and Cable Management CONNECT Edition V10

Bentley Raceway and Cable Management provides an integrated software system that includes 3D design and modeling of raceways, cable trays, and conduit systems, as well as routing and managing the cables that run through these systems.

Design raceway and cable systems in one product using Bentley Raceway and Cable Management software. Save time and reduce cost with the first and only integrated system for layout, routing, and material estimating. Fast track your next project with automated workflows for conceptual and detailed design phases. Prevent construction delays by using an intelligent 3D model to spot clashes, ensure spacing, and get accurate take offs.

Tech Talk Benefits of Using Bentley Raceway and Cable Management CONNECT Edition


Bentley Systems is a software development company that supports the professional needs of those responsible for creating and managing the world’s infrastructure.

Product: Bentley Raceway and Cable Management
Version: CONNECT Edition V10 (10.00.00.127)
Supported Architectures: x64
Website Home Page : www.bentley.com
Language: english
System Requirements: PC *
Size: 7.0 Gb

Raceway and Cable Management CONNECT Edition V10

Here compatibility across different release versions of Bentley Raceway and Cable Management Product with Operating Systems, ProjectWise and various Database types is presented.

Raceway and Cable Management CONNECT Edition V10

Important Notes:
- Bentley raceway and Cable Management CONNECT Edition is a 64-bit application, Compatible only with 64-bit Operating Systems.
- Bentley raceway and Cable Management supports Microsoft Office 64 bit and 32 bit versions.
- Microsoft Excel must be installed to import cable and equipment information from spreadsheets. Importing from .XLSX files is only possible when Excel 2010 or higher is installed.